Proximity detection systems do not perform to specification, caused by:
- Fails to alarm
- Fails to disengage at increased speed or nominated distance
- System fails to switch to camera that is in direction of sensed item
- False negative – fails to detect pedestrian or other vehicle
This Credible Failure mode is addressed by:
- BI-01P.08 Alarm and vehicle information panel expected response – information prepared for Operators
- BI-02D.53 Operator display specifications are detailed for mobile equipment
- BI-04S.20 Proximity detection data send
- BI-04T.20 Proximity detection, alerts, advice, and intervention equipment operating skills for overload conditions
CFM 1CD-02 Proximity alarms / area guards do not perform to specification
Last Updated: 03/08/2020 09:14:59am