Equipment system status alarms do not operate, caused by:
- Less than 8 volt supply
- Alarm system is not fail-to-safe
- Sensor failure / circuit failure
- Shorted to ground
- Software version is incorrect
This Credible Failure mode is addressed by:
- BI-01T.01 Required emergency checks before vehicle operation – information for operator by vehicle type.
- BI-02D.01 Fit-for-purpose equipment selection and site use approval processes
- BI-02P.01 All safety and operational systems on mobile equipment are maintained
- BI-02S.30 Equipment systems data send
- BI-02T.30 Component alarm or safety device compromise data send
- BI-03S.20 Speed and other operating parameter data send
- BI-04S.20 Proximity detection data send
- BI-05P.04 Skilled and experienced personnel are accountable for specifying and selecting mobile equipment and mobile equipment components
CFM 2ES-02 Installed equipment system status alarms do not operate
Last Updated: 04/08/2020 04:17:03pm